M2 Tap Drill Size

M2 tap drill size is 1.6 mm (0.063 in) for the standard M2 x 0.4 thread. All four charts we read that list M2 agree: Starrett, Champion Cutting Tool, Emuge and Hartner (Gühring group). It leaves about 77% thread inside the class 6H range of 1.567 to 1.679 mm.

The usual M2 is the coarse 0.4 mm pitch. Bolt Depot's metric chart, the fifth we use on bigger sizes, starts at M3, so it has no figure here. On M2 the drill choice is tight in a way it isn't on larger screws: the 6H band is 0.112 mm wide, and every 0.05 mm of drill diameter moves the thread by about 10 points.

M2 drills from #53 to #51

Thread left is (2 − hole) / (1.299 x 0.4), the OSG formula. On M2 class 6H allows about 62% to 83% thread. Diameters from Wikipedia.

DrillDiameterThread leftClass 6H
#531.511 mm (0.0595 in)94%Under the min by 0.056 mm
1.55 mm1.550 mm87%Under the min by 0.017 mm
1/16 in1.588 mm (0.0625 in)79%Inside
1.6 mm1.600 mm77%Inside
#521.613 mm (0.0635 in)74%Inside
1.65 mm1.650 mm67%Inside
1.7 mm1.700 mm58%Over the max by 0.021 mm
#511.702 mm (0.0670 in)57%Over the max by 0.023 mm

Four drills pass, two metric and two inch. A 1/16 in bit from a fractional set is a fine M2 tap drill, and #52 from a number set is just as good. 1.7 mm looks like the natural next step after 1.6 mm, and it is the one to avoid: the hole is over 6H and the thread is down to about 58%.

M2 and M.2 SSD screws

The M.2 slot for SSDs often takes a small M2 screw. Crucial's support page calls an M2x0.4mm screw a relatively common replacement size, and the size it supplies with some of its drives. If you are making or repairing a standoff or a bracket for one, that is an M2 x 0.4 hole, drilled at 1.6 mm. Check the board or laptop manual first, because some use another size.

Why M2 is tight

The thread on M2 is very shallow. Basic thread depth on the nut is 0.541266 x pitch, which is 0.217 mm here, and the whole 6H band is 0.112 mm. A 0.05 mm drill step costs about 10 points of thread on M2, against about 1.5 points on M20. So a drill that runs a little oversize, or a hole drilled off-axis, matters more here than on any bigger metric size on this site. A drill that cuts slightly big is a reason to start at 1.6 mm, not 1.65 mm.

M2 vs #2-56

#2-56 is 2.18 mm across, a little bigger than M2, with 56 threads per inch (0.454 mm pitch). Their drills don't cross over. 1.6 mm is 0.094 mm under the #2-56 class 2B minimum of 1.694 mm, from the OSG chart, and #50, the #2-56 drill, is 1.778 mm, 0.099 mm over the M2 6H maximum.

M2 inserts and form taps

None of the insert tables we use cover M2: the Hartner wire thread insert table starts at M4 and the Albany County Fasteners chart at M3. For a forming tap, Balax gives 1.85 mm; the Jarvis and Haas charts have no M2 row. For an insert, use the drill the insert maker gives.

FAQ

What is the M2 tap drill size?

M2 tap drill size is 1.6 mm (0.063 in) for the standard M2 x 0.4 thread, about 77% thread inside class 6H.

What inch drill for M2?

1/16 in (1.588 mm) gives about 79% thread and passes 6H. A #52 (1.613 mm) also passes, at about 74%.

Is 1.7 mm OK for M2?

No. 1.7 mm is 0.021 mm over the 6H maximum of 1.679 mm and leaves only about 58% thread. 1.65 mm is the biggest common size that passes.

What thread are M.2 SSD screws?

Often M2 x 0.4, though Crucial notes M.2 screw sizes are not standardized in all systems. It calls M2x0.4mm a relatively common replacement screw, and it is the size Crucial supplies with some of its drives. A standoff for one takes a 1.6 mm drill.

Can I use the M2 drill for #2-56?

No. 1.6 mm is 0.094 mm under the #2-56 class 2B minimum of 1.694 mm, and #2-56's own #50 drill is 0.099 mm over the M2 6H maximum.

Related pages

Cite or reuse this data

Please quote these figures with a link to this page: TapDrillSize, "M2 tap drill size", https://tapdrillsize.com/m2-tap-drill-size/, published November 28, 2026. Every row is in the CSV download. If a number is wrong, write to contact@tapdrillsize.com and we will correct it.

Chart drills from Starrett, Champion Cutting Tool, Emuge and Hartner (Gühring group); Bolt Depot's metric chart has no M2 row. Class 6H limits from Emuge and Hartner (Gühring group). #2-56 class 2B limits and the thread percentage formula from the OSG chart. M.2 screw size from Crucial. Form tap drill from Balax. Drill diameters from Wikipedia. Published on November 28, 2026.