M20 Tap Drill Size
M20 tap drill size is 17.5 mm (0.689 in) for the standard M20 x 2.5 coarse thread. All four charts we read that list M20 print 17.5 mm: Starrett, Champion Cutting Tool, Emuge and Hartner (Gühring group). It leaves about 77% thread inside the class 6H range of 17.294 to 17.744 mm.
Bolt Depot's metric chart, the fifth we use for smaller sizes, does not list M20. That matters less than it might, because on every size from M4 to M16 Bolt Depot was the chart that printed a bigger drill than the rest. At M20 the charts that remain agree.
Four charts, one answer
| Chart | Business | Drill | Thread | 6H |
|---|---|---|---|---|
| Starrett | Tool maker | 17.5 mm | 77% | Inside |
| Champion Cutting Tool | Tool maker | 17.5 mm | 77% | Inside |
| Emuge | Tap maker | 17.5 mm | 77% | Inside |
| Hartner (Gühring group) | Drill maker | 17.5 mm | 77% | Inside |
17.5 mm is the major diameter minus the pitch, 20 − 2.5, and the OSG formula puts it at about 77%: (20 − hole) / (1.299 x 2.5). The 6H band here is 0.450 mm wide, so the drill has some room either side.
M20 pitches, and the cable gland thread
Metric cable glands use a fine 1.5 mm pitch: Palazzoli lists gland screwcaps in M20X1.5 alongside other sizes from M12X1.5 to M63X1.5. M20 x 1.5 needs an 18.5 mm drill, a whole millimetre more than the coarse thread. From the Hartner chart:
| Thread | Tap drill | 6H hole limits |
|---|---|---|
| M20 x 2.5 (coarse) | 17.5 mm | 17.294 to 17.744 mm |
| M20 x 2 | 18.0 mm | 17.835 to 18.210 mm |
| M20 x 1.5 | 18.5 mm | 18.376 to 18.676 mm |
| M20 x 1 | 19.0 mm | 18.917 to 19.153 mm |
The four bands are separate, so every pitch needs its own drill. For an enclosure tapped to take an M20 gland, use 18.5 mm, not 17.5 mm.
Drills near 17.5 mm for coarse M20
Diameters from Wikipedia:
| Drill | Diameter | Thread left | Class 6H |
|---|---|---|---|
| 17.25 mm | 17.250 mm | 85% | Under the min by 0.044 mm |
| 17.3 mm | 17.300 mm | 83% | Inside |
| 17.4 mm | 17.400 mm | 80% | Inside |
| 11/16 in | 17.463 mm (0.6875 in) | 78% | Inside |
| 17.5 mm | 17.500 mm | 77% | Inside |
| 17.6 mm | 17.600 mm | 74% | Inside |
| 17.7 mm | 17.700 mm | 71% | Inside |
| 17.75 mm | 17.750 mm | 69% | Over the max by 0.006 mm |
Every 0.1 mm step from 17.3 to 17.7 mm passes. The inch drill to use is 11/16 in, only 0.037 mm under 17.5 mm.
M20 vs 3/4-10
The nearest inch thread, 3/4-10, is 19.05 mm across with a 2.54 mm pitch. Its standard drill, 21/32 in (16.669 mm), is 0.625 mm under the M20 6H minimum, and the two threads do not fit each other.
Depth and form taps
For a blind M20 hole, add at least 4 threads below the thread, 10 mm on this pitch (ToolGrit). For the 20 to 30 mm of thread ToolGrit's strength figures assume, that is 30 to 40 mm of full-diameter depth before the drill point.
For a forming tap, Jarvis gives 18.75 mm and Haas 18.9 mm. Balax's metric form tap chart does not list M20.
FAQ
What is the M20 tap drill size?
M20 tap drill size is 17.5 mm (0.689 in) for the standard M20 x 2.5 coarse thread, about 77% thread inside class 6H.
What drill for an M20 x 1.5 cable gland thread?
18.5 mm, per the Hartner chart, with 6H limits of 18.376 to 18.676 mm. The coarse 17.5 mm drill is too small for it.
What inch drill for M20?
11/16 in (17.463 mm), about 78% thread, inside class 6H.
Can I use the 3/4-10 drill for M20?
No. 3/4-10 takes 21/32 in (16.669 mm), 0.625 mm under the M20 6H minimum.
How deep should a blind M20 hole be?
At least 10 mm (4 threads of 2.5 mm) deeper than the thread. For 20 mm of thread, 30 mm of full-diameter depth before the drill point.
Related pages
Cite or reuse this data
Please quote these figures with a link to this page: TapDrillSize, "M20 tap drill size", https://tapdrillsize.com/m20-tap-drill-size/, published November 21, 2026. Every row is in the CSV download. If a number is wrong, write to contact@tapdrillsize.com and we will correct it.
Chart drills from Starrett, Champion Cutting Tool, Emuge and Hartner (Gühring group); Bolt Depot's metric chart has no M20 row. The 3/4-10 drill is the standard one in the inch charts on this site. Class 6H limits from Emuge and Hartner (Gühring group), fine pitch rows from Hartner (Gühring group). Thread percentage formula from the OSG chart. Cable gland threads from Palazzoli. Blind hole depth from ToolGrit. Form tap drills from Jarvis and Haas. Drill diameters from Wikipedia. Published on November 21, 2026.